1. Industries
  2. Marine
  3. Offshore support vessels
  4. Living quarters

Further sealing solutions for your living quarters

Roxtec provides complete and certified solutions for cables, metal pipes and plastic pipes penetrating decks and bulkheads in accommodation and service areas.

Why use Roxtec?

  • Firestop
  • Dust-tight

Superior simplicity

  • One opening for dozens of cables and pipes
  • Flexibility for cables and pipes of different sizes
  • Suitable for black and grey water applications
Sealing solution options
Roxtec S transit

Roxtec S transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit for welding to the structure.

For welding into precise aperture

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SF transit

Roxtec SF transit

fire rated.svg
watertight.svg
gas-tight.svg

Cable and pipe transit with metal frame and flange for welding to the structure.

For wide aperture tolerance when welding

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SPM™ seal

Roxtec SPM™ seal

fire rated.svg
watertight.svg
gas-tight.svg

Seal for metal pipes for use when welding is not allowed, recommended or desired.

Easy installation without welding

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 0.67 bar (catastrophic)
  • Water: 1 bar (catastrophic)
Roxtec RS seal

Roxtec RS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

For installation in existing sleeves or core drilled holes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec RS PPS seal

Roxtec RS PPS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for large single plastic pipes.

For installation in existing sleeve

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 2 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec RS PPS/S seal

Roxtec RS PPS/S seal

fire rated.svg
watertight.svg
gas-tight.svg

Light-weight plastic pipe seal for single-side installation.

For installation in existing sleeve

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60

Tightness

  • Gas: 2 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec Sleev-it™ Fire penetration seal

Roxtec Sleev-it™ Fire penetration seal

fire rated.svg

Fire penetration seal for single plastic pipes.

For fire rated divisions

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • B-CLASS according to IMO 2010 FTP Code

Tightness

  • N/A
Roxtec Sleev-it™ Waterproof penetration seal

Roxtec Sleev-it™ Waterproof penetration seal

fire rated.svg
watertight.svg

Penetration seal for plastic pipes for basic protection against fire, gas and water.

Waterproof seal for exact/fixed pipe diameters

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • B-CLASS according to IMO 2010 FTP Code

Tightness

  • Water: 1 bar (catastrophic)
Roxtec Sleev-it™ transition collar

Roxtec Sleev-it™ transition collar

fire rated.svg

Fire protection collar for connections between steel and plastic pipes.

For connections between steel and plastic pipes.

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • B-CLASS according to IMO 2010 FTP Code

Tightness

  • N/A
Roxtec R transit

Roxtec R transit

fire rated.svg
watertight.svg
gas-tight.svg

Round transit for sealing around multiple cables and pipes in a limited area.

For installation in existing sleeves

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)