1. Industries
  2. Power
  3. Offshore wind power
  4. Offshore substations

Further sealing solutions for your offshore substations

Roxtec A-60/A-0 fire rated and IP rated seals are ideal for all kinds of offshore applications, such as steel decks and walls, sandwich panels, roof-top entries and cabinets. Use them to secure HVDC converter stations, AC substations, transformer rooms and GIS as well as medium and low voltage areas.

Why use Roxtec?

  • Watertight
  • Firestop
  • Area efficiency
  • EMI/EMP protection
  • Cable retention

Superior simplicity

  • Flexibility for cables and pipes of different sizes
  • Built-in spare capacity for future cables and pipes
  • EMC solutions for electrical safety
  • One supplier supporting from design to inspection
Sealing solution options
Roxtec S transit

Roxtec S transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit for welding to the structure.

For welding into precise aperture

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SF transit

Roxtec SF transit

fire rated.svg
watertight.svg
gas-tight.svg

Cable and pipe transit with metal frame and flange for welding to the structure.

For wide aperture tolerance when welding

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec GH transit

Roxtec GH transit

fire rated.svg
ip-ul nema.svg
gas-tight.svg

Transit with flange, for casting or bolting.

For casting or bolting on to even structures

Fire

  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E60
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67
  • IP 68
Roxtec RS seal

Roxtec RS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

For installation in existing sleeves or core drilled holes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec RS BG™ seal with SLF RS BG

Roxtec RS BG™ seal with SLF RS BG

fire rated.svg
watertight.svg
gas-tight.svg
electrical saftey.svg

Penetration seal for bonding and grounding of a single cable or pipe, for bolting to even structures.

For bonding and grounding applications.

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 0.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)

Supports

  • Bonding and grounding
Roxtec R transit

Roxtec R transit

fire rated.svg
watertight.svg
gas-tight.svg

Round transit for sealing around multiple cables and pipes in a limited area.

For installation in existing sleeves

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)