1. Industries
  2. Offshore oil & gas
  3. Semi-submersible rigs and platforms
  4. Outdoor deck area

Further sealing solutions for your outdoor deck area

Roxtec cable and pipe sealing solutions provide the flexibility you need onsite to handle an unexpected number of armored cables and pipes of different diameters. Use the transits in walls, floors and equipment in demanding outdoor environments.

Why use Roxtec?

  • Watertight
  • Firestop
  • Corrosion resistant
  • Explosion protection

Superior simplicity

  • One opening for dozens of cables and pipes
  • Flexibility for cables and pipes of different sizes
  • Built-in spare capacity for upgrades and retrofits
  • EMC solutions for bonding and grounding
Sealing solution options
Roxtec S transit

Roxtec S transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit for welding to the structure.

For welding into precise aperture

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SRC r20 transit

Roxtec SRC r20 transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit with metal frame for load-bearing structures.

Corner radius 20mm

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SRC r40 transit

Roxtec SRC r40 transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit with metal frame for load-bearing structures.

Corner radius 40mm

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SF transit

Roxtec SF transit

fire rated.svg
watertight.svg
gas-tight.svg

Cable and pipe transit with metal frame and flange for welding to the structure.

For wide aperture tolerance when welding

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec RS seal

Roxtec RS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

For installation in existing sleeves or core drilled holes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec R transit

Roxtec R transit

fire rated.svg
watertight.svg
gas-tight.svg

Round transit for sealing around multiple cables and pipes in a limited area.

For installation in existing sleeves

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec HD transits

Roxtec HD transits

ip-ul nema.svg

High cable density transit devices with frame in 316L.

For harsh and hazardous environments

Fire

  • N/A

Tightness

  • IP 66/67
  • UL/NEMA 4,4X,12,13