1. Industries
  2. Manufacturing industry
  3. Rolling stock
  4. Floor

Further sealing solutions for your floor

Roxtec bolted and welded transits are ideal for demanding floor applications. A wide range of frames with varying packing space and frame depth makes design work easy.

Why use Roxtec?

  • Fire rated
  • Watertight
  • Air-shock protection

Superior simplicity

  • Built-in spare capacity
  • Welded or bolted sealing solutions
  • Flexibility for cables, pipes and conduits of different sizes
Sealing solution options
Roxtec S transit

Roxtec S transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit for welding to the structure.

For welding into precise aperture

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec G transit

Roxtec G transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit with flange, for welding.

For welding

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec GH transit

Roxtec GH transit

fire rated.svg
ip-ul nema.svg
gas-tight.svg

Transit with flange, for casting or bolting.

For casting or bolting on to even structures

Fire

  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E60
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67
  • IP 68
Roxtec RS seal

Roxtec RS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

For installation in existing sleeves or core drilled holes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec R transit

Roxtec R transit

fire rated.svg
watertight.svg
gas-tight.svg

Round transit for sealing around multiple cables and pipes in a limited area.

For installation in existing sleeves

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec C LW/K Transit

Roxtec C LW/K Transit

fire rated.svg
ip-ul nema.svg

Light weight transit for welding to the structure.

Light-weight cable and pipe transit for fire protection

Fire

  • E/EI rating according to EN 45545 E30

Tightness

  • IP 66
Roxtec C LH Transit

Roxtec C LH Transit

fire rated.svg
ip-ul nema.svg

Light weight transit for bolting to the structure.

Light-weight cable and pipe transit for fire protection

Fire

  • E/EI rating according to EN 45545 E30

Tightness

  • IP 66