Roxtec sealing solutions are ideal when multiple cables or pipes of different types need to penetrate any type of wall or floor and the structure must meet specific safety ratings. Keep your site dry and protect equipment from humidity and rodents.

Why use Roxtec?

  • Watertight
  • Firestop
  • Gas-tight
  • Dust-tight
  • Pest and rodent barrier
  • EMI/EMP protection
  • Cable retention

Superior simplicity

  • One opening for dozens of cables, pipes or conduit
  • Flexibility for cables and pipes of different sizes
  • Built-in spare capacity for upgrades and retrofits
  • Solutions for underground applications
  • Installation in wet conditions and running water
Sealing solution options
Roxtec GH transit

Roxtec GH transit

fire rated.svg
ip-ul nema.svg
gas-tight.svg

Transit with flange, for casting or bolting.

For casting or bolting on to even structures

Fire

  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E60
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67
  • IP 68
Roxtec GH BG™ transit

Roxtec GH BG™ transit

fire rated.svg
ip-ul nema.svg
electrical saftey.svg
gas-tight.svg

Transit with flange and earthing terminal, for bolting onto even structures.

For bolting to steel or sandwich walls with ground connection

Fire

  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67

Supports

  • Bonding and grounding
Roxtec GH FL100 transit

Roxtec GH FL100 transit

fire rated.svg
ip-ul nema.svg
gas-tight.svg

Transit with wide flange, for bolting onto uneven structures.

For bolting to concrete/bricks

Fire

  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67
Roxtec GH BG™ FL100 transit

Roxtec GH BG™ FL100 transit

fire rated.svg
ip-ul nema.svg
electrical saftey.svg
gas-tight.svg

Transit with wide flange and earthing terminal, for bolting onto uneven structures.

For bolting to concrete/bricks with ground connection

Fire

  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67
  • IP 68

Supports

  • Bonding and grounding
Roxtec RS seal

Roxtec RS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

For installation in existing sleeves or core drilled holes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec RS BG™ seal

Roxtec RS BG™ seal

fire rated.svg
watertight.svg
gas-tight.svg
electrical saftey.svg

Penetration seal for bonding and grounding of a single cable or pipe.

For bonding and grounding applications.

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 2 bar (catastrophic)
  • Water: 4 bar (catastrophic)

Supports

  • Bonding and grounding
Roxtec RS BG™ seal with SLF RS BG

Roxtec RS BG™ seal with SLF RS BG

fire rated.svg
watertight.svg
gas-tight.svg
electrical saftey.svg

Penetration seal for bonding and grounding of a single cable or pipe, for bolting to even structures.

For bonding and grounding applications.

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 0.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)

Supports

  • Bonding and grounding
Roxtec R transit

Roxtec R transit

fire rated.svg
watertight.svg
gas-tight.svg

Round transit for sealing around multiple cables and pipes in a limited area.

For installation in existing sleeves

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec H3 seal

Roxtec H3 seal

fire rated.svg
watertight.svg
gas-tight.svg
ip-ul nema.svg

Openable transit for sealing around existing cables/pipes.

For cables in trefoil formation

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
  • IP 68
Roxtec knock-out sleeve

Roxtec knock-out sleeve

watertight.svg
gas-tight.svg
ip-ul nema.svg

Sleeve with knock-out plate for sealing prior to cable and pipe routing.

Sleeve with knock-out plate for casting into concrete

Fire

  • N/A

Tightness

  • Gas: 0.3 bar (constant)
  • Water: 0.5 bar (constant)
  • IP 68
Roxtec H3 UG™ seal

Roxtec H3 UG™ seal

watertight.svg
gas-tight.svg
ip-ul nema.svg

Transit for cables entering via foundations.

For cables in trefoil formation

Fire

  • N/A

Tightness

  • Gas: 0.3 bar (constant)
  • Water: 0.5 bar (constant)
  • IP 68
Roxtec RS UG™ seal

Roxtec RS UG™ seal

watertight.svg
gas-tight.svg
ip-ul nema.svg

Round seal for single cables and pipes entering via foundations.

For single cables and pipes

Fire

  • N/A

Tightness

  • Gas: 0.3 bar (constant)
  • Water: 0.5 bar (constant)
  • IP 68
Roxtec R UG™ transit

Roxtec R UG™ transit

watertight.svg
gas-tight.svg
ip-ul nema.svg

Transit in flexible configuration for multiple cables and pipes entering via foundations.

For multiple cables and pipes

Fire

  • N/A

Tightness

  • Gas: 0.3 bar (constant)
  • Water: 0.5 bar (constant)
  • IP 68