1. Industries
  2. Power
  3. Nuclear
  4. Walls & floors

Further sealing solutions for your walls & floors

Roxtec sealing solutions are ideal when multiple cables and pipes of different types and sizes enter walls, floors, or underground. They secure protection by maintaining barriers and separation of key functions such as power supply, emergency back-up power, monitoring, control, pumping, cooling, and turbine and generation activities. The seals meet international safety ratings and withstand harsh environments. Use our seals to simplify design, save space and manage high cable density. You can maintain the safety level at very high fill ratio and benefit from instant performance as there is no need for drying or curing.

Why use Roxtec?

  • Watertight
  • Firestop
  • Gas-tight
  • Dust-tight
  • EMI protection
  • Pest and rodent barrier
  • Bonding and grounding

Superior simplicity

  • One openings for dozens of cables and pipes
  • Flexibility for cables and pipes of different sizes
  • Built-in spare capacity for last-minute changes
  • Documentation for cable management and maintenance
  • Standardization and unified specification made easy
Sealing solution options
Roxtec S transit

Roxtec S transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit for welding to the structure.

For welding into precise aperture

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec GH transit

Roxtec GH transit

fire rated.svg
ip-ul nema.svg
gas-tight.svg

Transit with flange, for casting or bolting.

For casting or bolting on to even structures

Fire

  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E60
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67
  • IP 68
Roxtec GH FL100 transit

Roxtec GH FL100 transit

fire rated.svg
ip-ul nema.svg
gas-tight.svg

Transit with wide flange, for bolting onto uneven structures.

For bolting to concrete/bricks

Fire

  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67
Roxtec GH BG™ FL100 transit

Roxtec GH BGâ„¢ FL100 transit

fire rated.svg
ip-ul nema.svg
electrical saftey.svg
gas-tight.svg

Transit with wide flange and earthing terminal, for bolting onto uneven structures.

For bolting to concrete/bricks with ground connection

Fire

  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67
  • IP 68

Supports

  • Bonding and grounding
Roxtec GKO transit

Roxtec GKO transit

fire rated.svg
ip-ul nema.svg

Transit with a frame to bolt into different combinations.

For retrofit installation when bolting

Fire

  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479

Tightness

  • IP 66/67
  • IP 68
Roxtec RS seal

Roxtec RS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

For installation in existing sleeves or core drilled holes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec RS seal with SLFO/RI

Roxtec RS seal with SLFO/RI

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

Includes openable sleeve for installation around existing cables/pipes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 1 bar (catastrophic)
  • Water: 2 bar (catastrophic)
Roxtec R transit

Roxtec R transit

fire rated.svg
watertight.svg
gas-tight.svg

Round transit for sealing around multiple cables and pipes in a limited area.

For installation in existing sleeves

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)