Roxtec cable and pipe transits keep tight and help you avoid cracks in decks and bulkheads. Use our fire rated seals with rounded corners to reduce the mechanical stress. 

Why use Roxtec?

  • Watertight
  • Firestop
  • Mechanical stress reduction

Superior simplicity

  • One opening for dozens of cables and pipes
  • Flexibility for cables and pipes of different sizes
  • Built-in spare capacity for upgrades and retrofits
Sealing solution options
Roxtec S transit

Roxtec S transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit for welding to the structure.

For welding into precise aperture

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SRC r20 transit

Roxtec SRC r20 transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit with metal frame for load-bearing structures.

Corner radius 20mm

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SRC r40 transit

Roxtec SRC r40 transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit with metal frame for load-bearing structures.

Corner radius 40mm

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SF transit

Roxtec SF transit

fire rated.svg
watertight.svg
gas-tight.svg

Cable and pipe transit with metal frame and flange for welding to the structure.

For wide aperture tolerance when welding

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SK transit

Roxtec SK transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit with extra deep metal frame for welding to the structure.

Extra deep transit

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SBTB transit

Roxtec SBTB transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit with metal frame for an extra level of fire protection.

For high fire demands

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec RS seal

Roxtec RS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

For installation in existing sleeves or core drilled holes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec R transit

Roxtec R transit

fire rated.svg
watertight.svg
gas-tight.svg

Round transit for sealing around multiple cables and pipes in a limited area.

For installation in existing sleeves

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)