1. Industries
  2. Power
  3. Distribution
  4. Cabinets & enclosures

Further sealing solutions for your cabinets & enclosures

Roxtec multi-cable seals are superior to cable glands. Save significant size on cabinets, junction boxes and other enclosures and reduce engineering hours spent on cable gland configurations.

Why use Roxtec?

  • Watertight
  • Firestop
  • Smoke-tight
  • Dust-tight
  • Pest and rodent barrier
  • Cable retention

Superior simplicity

  • One cut-out for dozens of pre-terminated cables
  • Flexibility for cables and pipes of different sizes
  • Built-in spare capacity for future cables and pipes
  • EMC solutions for electrical safety
Sealing solution options
Roxtec GH transit

Roxtec GH transit

fire rated.svg
ip-ul nema.svg
gas-tight.svg

Transit with flange, for casting or bolting.

For casting or bolting on to even structures

Fire

  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E60
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67
  • IP 68
Roxtec GH BG™ transit

Roxtec GH BG™ transit

fire rated.svg
ip-ul nema.svg
electrical saftey.svg
gas-tight.svg

Transit with flange and earthing terminal, for bolting onto even structures.

For bolting to steel or sandwich walls with ground connection

Fire

  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67

Supports

  • Bonding and grounding
Roxtec GHM transit

Roxtec GHM transit

fire rated.svg
watertight.svg
ip-ul nema.svg
gas-tight.svg

Transit for high cable density and large cables.

Light-weight transit for bolting

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501

Tightness

  • Gas: 1 bar (catastrophic)
  • Water: 2 bar (catastrophic)
  • IP 66/67
Roxtec GHM EMC transit for cabinets

Roxtec GHM EMC transit for cabinets

fire rated.svg
ip-ul nema.svg
emi protection.svg
watertight.svg
gas-tight.svg

Transit for EMC and high cable density.

Light-weight transit for bolting in EMC applications

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 1 bar (catastrophic)
  • Water: 2 bar (catastrophic)
  • IP 66/67

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec CF 8/32 transit

Roxtec CF 8/32 transit

ip-ul nema.svg

High cable density transit with aluminum frame.

For high demand areas

Fire

  • N/A

Tightness

  • IP 66/67
  • UL/NEMA 4,4X,12,13
Roxtec CF 8/32 BG™ transit

Roxtec CF 8/32 BG™ transit

ip-ul nema.svg
electrical saftey.svg

High cable density transit for bonding and grounding, with aluminum frame.

For bonding and grounding in high demand areas

Fire

  • N/A

Tightness

  • IP 66/67
  • UL/NEMA 4,4X,12,13

Supports

  • Bonding and grounding
Roxtec ComSeal™

Roxtec ComSeal™

ip-ul nema.svg

IP 55 rated entry seals with aluminum frame.

For cost-efficiency and flexibility in size

Fire

  • N/A

Tightness

  • IP 55
  • UL/NEMA 3,12,12K
Roxtec ComSeal™ EMC transit

Roxtec ComSeal™ EMC transit

ip-ul nema.svg
emi protection.svg

IP 54 rated cable entry seal for EMC.

For EMC and flexibility in size

Fire

  • N/A

Tightness

  • IP 54
  • UL/NEMA 3,12,12K

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec C RS T seal

Roxtec C RS T seal

ip-ul nema.svg

Round seal for single cable entries.

For single cable entry

Fire

  • N/A

Tightness

  • IP 66/67
  • IP 69K
  • UL/NEMA 4,4X,12,13