1. Industries
  2. Marine
  3. Naval vessels
  4. Water pipes

Further sealing solutions for your water pipes

Regardless of your preferred pipe material, Roxtec has the sealing solution. Our pipe seals are A-0 and A-60 approved for all metal and most plastic pipes. Use them to ensure watertight deck and bulkhead penetrations, to avoid the risk of water spreading from any leaking pipes and to be able to reopen the transits whenever you need.

Why use Roxtec?

  • Watertight
  • Firestop
  • Vibration damping
  • Certified solution

Superior simplicity

  • Easy and safe installation of pipes
  • Can be used for fresh, chilled and waste water
Sealing solution options
Roxtec S transit

Roxtec S transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit for welding to the structure.

For welding into precise aperture

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec S transit with SE PPS

Roxtec S transit with SE PPS

fire rated.svg
watertight.svg
gas-tight.svg

Transit for multiple plastic pipes.

For welding into precise opening

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec SPM™ seal

Roxtec SPM™ seal

fire rated.svg
watertight.svg
gas-tight.svg

Seal for metal pipes for use when welding is not allowed, recommended or desired.

Easy installation without welding

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 0.67 bar (catastrophic)
  • Water: 1 bar (catastrophic)
Roxtec RS seal

Roxtec RS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

For installation in existing sleeves or core drilled holes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec RS X seal

Roxtec RS X seal

fire rated.svg
watertight.svg
gas-tight.svg

Transit for use when welding is not allowed, recommended or desired.

For high pressure penetrations

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec RS OMD seal

Roxtec RS OMD seal

fire rated.svg
watertight.svg
gas-tight.svg

Transit with adaptable outside to fit non-standard sleeve sizes.

Flexible to fit non-standard sleeve sizes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec RS PPS seal

Roxtec RS PPS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for large single plastic pipes.

For installation in existing sleeve

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 2 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec Sleev-it™ Fire penetration seal

Roxtec Sleev-it™ Fire penetration seal

fire rated.svg

Fire penetration seal for single plastic pipes.

For fire rated divisions

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • B-CLASS according to IMO 2010 FTP Code

Tightness

  • N/A
Roxtec Sleev-it™ Waterproof penetration seal

Roxtec Sleev-it™ Waterproof penetration seal

fire rated.svg
watertight.svg

Penetration seal for plastic pipes for basic protection against fire, gas and water.

Waterproof seal for exact/fixed pipe diameters

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • B-CLASS according to IMO 2010 FTP Code

Tightness

  • Water: 1 bar (catastrophic)
Roxtec R X transit

Roxtec R X transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit for sealing around multiple cables and pipes in a limited area without welding or bolting.

For attachment through expansion

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)