Further sealing solutions for your command control room

Roxtec cable transits ensure electromagnetic shielding and protect equipment both inside, and around the command control room. Use our EMC solutions to secure data, communication and high-precision operation in order to improve survivability.

Why use Roxtec?

  • EMI/EMP protection
  • Watertight
  • Firestop
  • Gas-tight
  • Dust-tight
  • Blast load resistant

Superior simplicity

  • Flexibility for cables of different sizes
  • Built-in spare capacity for upgrades and retrofits
  • EMC solutions for electrical safety
Sealing solution options
Roxtec S transit

Roxtec S transit

fire rated.svg
watertight.svg
gas-tight.svg

Transit for welding to the structure.

For welding into precise aperture

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E60
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec RS seal

Roxtec RS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

For installation in existing sleeves or core drilled holes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec CF 8/32 transit

Roxtec CF 8/32 transit

ip-ul nema.svg

High cable density transit with aluminum frame.

For high demand areas

Fire

  • N/A

Tightness

  • IP 66/67
  • UL/NEMA 4,4X,12,13
Roxtec WaveGuide Seal ES (Welded)

Roxtec WaveGuide Seal ES (Welded)

fire rated.svg
watertight.svg
gas-tight.svg
ip-ul nema.svg
emi protection.svg

Penetration seal for electromagnetic shielding, for fiber optic cables.

For shielding and sealing of non-metallic fiber optic cables

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 0.67 bar (catastrophic)
  • Water: 2.5 bar (catastrophic)
  • IP 66/67

Supports

  • Electromagnetic shielding
Roxtec WaveGuide Seal ES (Bolted)

Roxtec WaveGuide Seal ES (Bolted)

fire rated.svg
watertight.svg
gas-tight.svg
ip-ul nema.svg
emi protection.svg

Penetration seal for Electromagnetic shielding, for fiber optic cables.

For shielding and sealing of non-metallic fiber optic cables

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 0.67 bar (catastrophic)
  • Water: 1 bar (catastrophic)
  • IP 66/67

Supports

  • Electromagnetic shielding