1. Industries
  2. Infrastructure
  3. Advanced facilities
  4. Building envelope

Further sealing solutions for your building envelope

Once a penetration for services is made, the structure is compromised. Use Roxtec cable and pipe seals to reinstate thermal, air and moisture protection as well as fire ratings. Make sure no dirty air or humidity enter your facility through electrical penetrations and ensure protection against rain and snow. Utility penetrations will never be a failure point in your building envelope since our seals provide long-lasting protection over the life of the facility. 

Why use Roxtec?

  • Air-tight
  • Watertight
  • Fire rated
  • Pest and rodent barrier

Superior simplicity

  • Easy and safe installation
  • Flexibility for cables and pipes of different sizes
  • Ensuring operational reliability of power systems
  • Long-term durability and protection
  • Built-in spare capacity for future cables and pipes
Roxtec FlamePlus™ transit

Roxtec FlamePlus™ transit

fire rated.svg
ip-ul nema.svg

Lightweight transit with built-in knock-out functionality

Composite frame in modular design

Fire

  • E/EI rating according to EN 13501

Tightness

  • IP 66
Roxtec GH transit

Roxtec GH transit

fire rated.svg
ip-ul nema.svg
gas-tight.svg

Transit with flange, for casting or bolting.

For casting or bolting on to even structures

Fire

  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E60
  • F/T rating according to UL 1479

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67
  • IP 68
Roxtec RS seal

Roxtec RS seal

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

For installation in existing sleeves or core drilled holes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
Roxtec R transit

Roxtec R transit

fire rated.svg
watertight.svg
gas-tight.svg

Round transit for sealing around multiple cables and pipes in a limited area.

For installation in existing sleeves

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • E/EI rating according to EN 45545 E30
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)